SP 800-137 Continuous Monitoring Course — RMF Coach

Continuous monitoring after the ATO: strategy, metrics, frequencies, automation, significant change, and assessing the program. Free educational course.

Baseline: NIST SP 800-137 and SP 800-137A, with the SP 800-37 Rev 2 Monitor step. Content as of 2026-11-16. 2 modules, 7 lessons, about 82 minutes.

Module 1 — Building the Monitoring Program

  • Explain ISCM, its three tiers and where it sits in the RMF
  • Write the strategy: metrics, assessment and monitoring frequencies, event-driven triggers and sampling
  • Judge when automated assessment and log feeds are ready to carry the load

Lesson 1 — ISCM Defined: Why the ATO Is Not the Finish Line (~9 min)

An authorization is a snapshot; continuous monitoring is how the decision stays true after the snapshot.

Explain what ISCM is, where it sits in the RMF, and which of the three tiers owns which decision.

Fourteen months after the ATO, Karen Diaz, the Authorizing Official for the Meridian Case Management System (MCMS), stops you in the hallway. "We authorized MCMS on what we knew last spring. Is that still a good decision today?"

You cannot answer from the authorization package alone. SP 800-137 explains why: an initial authorization is based on evidence from one point in time, but systems and their environments keep changing. New threats, new vulnerabilities, new technology and new missions all arrive after the signature.

Ongoing assessment of control effectiveness is what lets an authorization stay sound in that moving environment. Information security continuous monitoring, or ISCM, is how you answer Karen with current facts instead of last spring's report.

SP 800-137 defines ISCM as maintaining ongoing awareness of information security, vulnerabilities and threats so that leaders can make risk management decisions. The words "continuous" and "ongoing" do not mean every control is checked every second. They mean controls and risks are assessed and analyzed often enough to support risk-based decisions.

That is why the publication calls ISCM a tactic inside a larger strategy of organization-wide risk management. Its output informs risk responses, ongoing authorization, and how POA&M items are prioritized.

In the RMF it is Step 6, Monitor. SP 800-37 Rev 2 describes the purpose of Monitor as keeping ongoing situational awareness of the security and privacy posture of the system and the organization. One practical benefit: results from continuous monitoring can help satisfy the annual FISMA assessment requirement, as long as they are current, relevant, and produced by assessors with the required independence.

ISCM works at the same three tiers as organization-wide risk management.

Tier 1, the organization. Leaders set risk tolerance and governance. That tolerance drives the ISCM strategy for everyone below.

Tier 2, mission and business processes. Officials accountable for a mission set priorities for what must be monitored. Program Management controls are an example of controls managed here.

Tier 3, information systems. Most data collection happens here. System controls such as MCMS's are assessed, and the results flow up to inform the AO and the risk executive (function).

Roles follow the tiers. The CIO leads the organization's ISCM program. The senior information security officer (also called the SAISO or CISO in some agencies) establishes and maintains it. The AO makes sure it is applied to a given system, and the system owner writes the system-level strategy. SP 800-137 says "Information System Owner"; SP 800-37 Rev 2 says "System Owner." This course uses System Owner.

Lesson 2 — Writing the Strategy: Metrics and Frequencies (~14 min)

The strategy is where risk tolerance becomes a schedule: what you measure, and how often you look.

Set a defensible monitoring or assessment frequency for a control and say which factor justifies it.

SP 800-137 organizes ISCM into six steps: define the strategy, establish the program, implement it, analyze and report findings, respond to findings, and review and update the strategy and program. The process is recursive. What you learn in the last step reshapes the first.

Who writes what? The organization-wide strategy and policy are typically written at Tier 1, with general procedures at Tier 2. In SP 800-37 Rev 2 that is Task P-7, and the risk executive (function) approves it, including the minimum frequency for monitoring controls.

The system owner then writes a system-level strategy, Task S-5. It supplements the organization's strategy for the controls the organization does not cover. At a minimum, every control is assessed for effectiveness following the SSP and the SP 800-53A methods, including common and hybrid controls implemented at the system. Its output includes a time-based trigger for ongoing authorization.

A metric turns raw monitoring data into something a decision-maker can act on. SP 800-137 says metrics should come from specific objectives that maintain or improve security posture, and that system-level data can be rolled up so it is meaningful at each tier.

The publication's examples, offered only as illustrations: the number and severity of vulnerabilities found and fixed, unauthorized access attempts, configuration baseline information, contingency plan test dates and results, and the number of staff current on awareness training. A metric can blend data of different freshness, such as a daily scan and a quarterly review.

Here is the trap. A metric is only as good as the controls behind it. SP 800-137 compares collecting metrics from controls that were never assessed to weighing on a broken, uncalibrated scale. It adds that a dashboard can give a false sense of security if nobody keeps checking that its metrics are still relevant.

SP 800-137 lists the factors that push a frequency up or down:

Volatility. Controls that change often are assessed more often.

Impact level. Controls on High systems are monitored more often than on Moderate, and Moderate more than Low.

Critical functions. Items such as log management servers and firewalls are candidates for more frequent monitoring.

Known weaknesses. Controls with open POA&M items are monitored more often until fixed, and minor weaknesses less often than serious ones.

Risk tolerance, threat information, vulnerability information, risk assessment results and the output of strategy reviews.

Reporting requirements. They do not drive the strategy, but may influence frequency.

Worked example from the publication: CM-6 configuration settings and CM-8 component inventory change constantly, so they call for frequent, preferably automated, assessment. PS-3 personnel screening stays static for long periods, so it is assessed less often. Frequencies are not uniform and not permanent, and even parts of a single control can have different ones.

Calendars are not enough. An event-driven assessment is triggered by something outside the schedule: an incident, new threat information, a significant change to the system or its environment, new mission responsibilities, or the result of a security impact analysis or risk assessment. Depending on how significant the event is, it can lead to one or more reauthorizations. Write down the triggers and thresholds in the strategy before you need them.

Sometimes assessing every object is impractical, so you sample. The risk is that the sample misses variation in the full population. SP 800-137 points to SP 800-53A for coverage and names three criteria: enough types of objects, enough objects of each type, and enough specific objects per type to account for expected variance.

Be careful with picks that are not random, because they can introduce bias. Automated collection can reduce how much sampling you need.

Lesson 3 — Automation and Data Feeds (~11 min)

Automation lets you watch more, more often; the discipline is knowing when to trust it.

Decide whether an automated assessment is ready to replace a manual one, and what data feeds the AO can rely on.

SP 800-137 says to automate where you can, because automation lowers cost, improves reliability, and frees skilled people for work that needs judgment. It also says plainly that you cannot automate everything. Tools still need people to configure them and interpret what they find, and an early ISCM program will have several manual pieces. The strategy does not focus only on what is easy to collect.

When you choose tools, consider whether they pull data from a variety of sources, use open specifications such as SCAP, work with help desk, inventory, configuration and incident tools, can drill from summary metrics down to a single system, and can feed a SIEM or dashboard.

The architecture behind them needs four capabilities: data collection, storage, analysis, and retrieval and presentation. The goal is to collect data once and reuse it many times, with feeds from sources such as authorization packages, training records and system logs.

NISTIR 8011 Volume 1 describes an approach for automating control assessments to support continuous monitoring, ongoing assessment and ongoing authorization. The idea is simple: record the actual state of a system in machine-readable data, record the desired state in the same form, and compute the differences. A difference is a defect: the absence or failure of a control.

The prerequisites are machine-readable actual and desired state, a way to compute defects, a way to produce a human-readable report, and organizational thresholds for completeness and timeliness. The Test method from SP 800-53A is the easiest to automate; Examine and Interview involve people.

When can you trust it? The publication says automated assessment is adequate to replace a manual one as soon as it is at least as complete and at least as timely. Completeness means all relevant defect checks across all objects that could have the defect. Timeliness means each cycle runs at least as often as the strategy requires.

SP 800-137 lists system logs among the data feeds an ISCM architecture collects. For federal agencies, OMB Memorandum M-26-14 (May 22, 2026) sets the floor for logging. It rescinds M-21-31 and directs agencies to a risk-based, prioritized approach built on two objectives.

Continuous event monitoring (CEM) means logs and infrastructure that let you watch network activity in near real time and flag anomalies. Threat hunting, investigation, response and forensics (THIRF) means being able to investigate after a known or suspected compromise.

The minimum baseline in Appendix B: retained logs must be actively searchable for at least 6 months to support CEM, and retrievable for a year to support THIRF. Logs must be readily available to the agency's top-level security operations center, and must carry consistent, accurate timestamps. The memo does not apply to national security systems. It also requires an Agency Logging Plan and sets a maturity model measured by the percentage of systems at each level. Check CISA's logging reference architecture for current details.

Module 2 — Running and Judging the Program

  • Analyze findings, choose a risk response and keep the POA&M and reports current
  • Tell significant change from routine change and know who decides
  • Run an ongoing authorization review and assess the ISCM program itself

Lesson 4 — Triage: Analyze, Report and Respond (~12 min)

A finding is only useful when someone decides what to do about it and the paperwork shows it.

Route a monitoring finding to the right risk response and record it in the POA&M and assessment report.

This week's inventory check on MCMS finds a device nobody listed. SP 800-137 uses exactly this kind of finding as its worked example. If the inventory is inaccurate, the next question is why. Perhaps the process for connecting devices was ignored or is out of date, perhaps an asset tool is not working, or perhaps the organization is under attack.

The answer decides the response. Responsible parties might update the inventory, fix the process, train staff, or disconnect the stray device. And because monitoring is recursive, the finding may also trigger assessments of other controls.

SP 800-137 asks officials to analyze monitoring information against stated risk tolerance, the potential impact of the weakness on the system, mission and organization, and the impact of each mitigation option. Evolving threat and vulnerability data is always part of the analysis. Ask why first, then decide what.

At any tier, SP 800-137 lists four responses: mitigate, accept, avoid or reject, and share or transfer the risk, in line with organizational risk tolerance. In SP 800-37 Rev 2 the AO decides the response or approves what the system owner proposes, and the system owner or common control provider carries it out.

Two habits keep this honest. When the response is mitigation, the planned actions go in the POA&M and are tracked there. When the response is acceptance, the finding stays documented in the assessment report and keeps being monitored for changes in risk factors. SP 800-137 adds that the rationale for any decision is recorded under organizational policy.

Controls that are modified, enhanced or added as a response must be reassessed. And the plans, assessment reports and POA&M are updated on an ongoing basis without destroying information needed for oversight and audit.

One external deadline can override your own ranking. For FedRAMP-certified cloud services, the Consolidated Rules say providers should remediate vulnerabilities in CISA's Known Exploited Vulnerabilities catalog by the catalog due dates, even when fully mitigated, as required by CISA BOD 26-04 or its successor.

SP 800-137 says report content varies with the recipient, the frequency and the purpose. Its illustration, labeled illustrative only: the risk executive (function) might get a general annual report on all systems and a detailed quarterly report on high-impact systems. The CIO and senior information security officer might get quarterly technical detail. An AO might get monthly reports on the systems they authorize. An incident response team lead might get exception reports as alerts fire.

SP 800-37 Rev 2 adds that security and privacy posture reports can be time-driven, event-driven, or both, and flexible in form. At a minimum a report summarizes changes to the plans, assessment reports and POA&M since the last report. It should flow at intervals that inform without creating needless work. A tool-generated dashboard can count as the report if it meets the content requirements. Posture reporting is intended to be ongoing and does not require the formality of an initial authorization package.

Lesson 5 — Significant Change versus Routine Change (~12 min)

Most changes are handled by monitoring; a few reopen the authorization. Telling them apart is the skill.

Classify a proposed change as routine or significant, and know who decides what happens next.

SP 800-37 Rev 2 defines a significant change as one that is likely to substantively affect the security or privacy posture of a system. Its examples include a new or upgraded operating system, middleware or application; changes to ports, protocols or services; a new hardware platform; changes in how information, including PII, is processed; changes to cryptographic modules; changes in information types; and modifications to security and privacy controls.

The key words are "only significant when." Those examples count only when they are likely to affect posture, and each organization sets its own criteria, using mission needs, threat information, privacy risk and security categorization.

Event-driven triggers the publication lists include new threat or vulnerability information, a rise in findings, new missions, a change of AO, significant changes to the system or environment, supply chain changes, and exceeding organizational thresholds. Most changes can be handled through continuous monitoring and ongoing authorization.

The system owner conducts security impact analyses on changes to the system. That analysis, plus the organization's significant-change criteria, tells you which path a change takes.

If it is not significant, configuration management and continuous monitoring handle it, and the plans and POA&M are updated. If it looks significant, you tell the AO. SP 800-137 gives the AO the call: the AO determines whether significant changes require reauthorization actions and reauthorizes when required.

Two points keep this efficient. If an authorization action is started, SP 800-37 Rev 2 says to target only the controls affected by the change and reuse earlier assessment results wherever possible. And continuous monitoring should also watch for unauthorized changes, find their root cause, and respond. If the root cause is an attack, that could mean incident response; if staff skipped the change process, it may mean retraining.

For cloud providers with a FedRAMP Certification at Class B, C or D, the Consolidated Rules for 2026 give a decision order. The provider evaluates each potential significant change: is it a certification class change (which needs a new assessment)? If not, is it routine recurring? Is it transformative? Otherwise it is adaptive.

Routine recurring changes, such as routine patching, firewall rule updates or capacity changes, should not get a formal notification.

Adaptive changes, such as an operating system update with known breaking changes, need notice within 10 business days after finishing.

Transformative changes are rare and large, such as moving from virtual machines to containers or replacing a critical third-party service. They need notice at least 30 business days before starting, final plans at least 10 business days before, and notices after finishing and after verification, each within 5 business days.

Agencies see these in the certification data they review as part of their own monitoring. Effective dates vary by program type, so check the current rules.

Lesson 6 — Ongoing Authorization and the AO's View (~13 min)

Ongoing authorization turns the ATO from a three-year date into a standing decision the AO keeps renewing.

Decide whether a system is ready for ongoing authorization and run a time-driven or event-driven AO review.

A system may move from a point-in-time authorization to ongoing authorization when two conditions hold. First, it received its initial authorization based on a complete, zero-based review of the system or common controls. Second, an organizational continuous monitoring program is in place that monitors controls at the rigor and frequencies the strategy and NIST guidance require.

The AO acknowledges the transition and takes responsibility for the activities of ongoing authorization, then documents it by issuing a new authorization decision. That decision removes the termination date that bound the original one.

There are two kinds of review trigger. A time-driven trigger is the frequency the organization sets for the AO to review security and privacy information and authorize continued operation, per CA-6 part c. An event-driven trigger calls for an immediate review when something defined happens. The event review is in addition to the time-driven one. Ongoing assessment and ongoing authorization are different but closely related.

At each review, Task M-6 has the AO or designated representative review the posture reports, including the effectiveness of implemented controls, to decide whether current risk is acceptable. Inputs are the organization's risk tolerance, posture reports, the POA&M, risk assessment results and the plans.

The outcome is a determination of risk and either ongoing authorization to operate, or a denial: the AO can issue a denial of authorization to operate if risk is no longer acceptable. The AO directs the system owner or common control provider and conveys the updated determination to the risk executive (function).

Two cautions. For moderate and high-impact systems, the information the AO receives must come from an entity that meets the organization's independence requirements. And where automated tools do not generate enough information, manual assessments fill the gaps. For organizations new to this, SP 800-37 Rev 2 suggests starting with low-impact systems, where risk tolerance is likely greater.

A FedRAMP Certification is not an agency ATO. The agency's AO still issues its own authorization for the system that uses the cloud service, and the Collaborative Continuous Monitoring rules feed that agency's own ISCM.

Providers with Class B, C or D certification must send an Ongoing Certification Report (OCR) to all necessary parties every 3 months, covering the whole period since the last one. It summarizes changes to certification data, planned changes in at least the next three months, accepted vulnerabilities, transformative changes, updated recommendations, the agencies directly using the product, FedRAMP reportable incidents (or an attestation of none), and lessons learned from incidents. Where they apply, the provider also hosts a Quarterly Review: Class C and D must, Class B should.

Agencies must review each OCR to see how changes may affect the risk tolerance recorded in the agency's ATO, and should consider the ATO's Security Category when assigning staff to the review.

Lesson 7 — Assessing the ISCM Program (SP 800-137A) (~11 min)

Controls get assessed; so does the monitoring program itself, using a different set of questions.

Plan an ISCM program assessment and describe what it does and does not evaluate.

Ravi Menon is asked by the CIO: "How do we know our ISCM program works?" Individual control assessments will not answer that. SP 800-137A is written for exactly this. It gives organizations a method and criteria for evaluating the ISCM program itself: strategies, policies, procedures, metrics, analysis, reporting, risk response and the improvement process.

Its scope is deliberate. The assessment looks at the structure and governance of the program and does not evaluate monitoring technologies or the effectiveness of individual controls, which SP 800-53A covers. It is meant to be technology-neutral and scalable.

Two engagement types exist. Third-party assessments are independent, external or internal to the organization. Self-assessments are done by the organization's own staff, either as a distributed or a facilitated assessment, and can reveal shortcomings early. NIST's page for SP 800-137A notes that NISTIR 8212 offers an operational approach and a working implementation, ISCMAx.

The heart of SP 800-137A is its catalog of assessment elements: statements about attributes of the ISCM program that an assessor evaluates. The catalog has 128 elements; 89 are derived from SP 800-137 and 39 from other sources. Each element is tied to one of the six ISCM process steps, and the first digit of its ID is that step. Examples include having an organization-wide policy for security status monitoring, and following procedures at the documented frequencies.

Elements can be linked in chains for traceability, for example completeness of data collected, timeliness, automation, and use in reviews.

The default judgment is Satisfied or Other than Satisfied, with annotations that explain any Other than Satisfied. Organizations may add a Partially Satisfied value or more granular scales. Scoring is optional: each judgment can be scored, scores can be weighted by criticality, and totals can be shown as a percentage of the best possible score.

The engagement has three steps: Plan, Conduct and Report. The ISCM Program Assessment Plan records the type of assessment, scope, staffing, roles, schedule, milestones, tailoring decisions and the type of report. For a third-party assessment, the assessing team writes the plan for the organization's approval. For a self-assessment, organizational leadership who will act on the results approve it.

Scope is flexible. The Define step is always included so the foundation is evaluated, and the assessment can stop at any later step: Establish, Implement, or a full run through Review and Update.

In the Report step, assessors draft findings and recommendations, leadership reviews the draft, and a final report follows. The organization is then accountable for responding: analyze findings, prioritize response actions according to risk tolerance, assign roles and time frames, and document the plan in a POA&M or an organization-defined format. It can also confirm fixes by reassessing the related elements.

RMF Coach is an educational simulation and training product — not an authorization, and not affiliated with or endorsed by NIST or FedRAMP.