Protecting CUI: SP 800-171 Rev 3 Course — RMF Coach
What CUI is, how SP 800-171 Rev 3 and 171A work, and why 32 CFR 170.14 still pins Rev 2. Current as of November 2026. Free educational course.
Baseline: NIST SP 800-171 Rev 3 and SP 800-171A Rev 3. Content as of 2026-11-16. 3 modules, 7 lessons, about 26 minutes.
Module 1 — The Standard: What It Protects and Where It Comes From
- Define CUI and name who runs the CUI program, who writes the security requirements, and who makes them binding
- Explain how SP 800-171 was derived from the SP 800-53 Moderate baseline
- Describe what changed in Rev 3, including organization-defined parameters and withdrawn requirements
Lesson 1 — What CUI Is and Who Owns the Program (~4 min)
Before you protect it, know what it is and whose rules you are following.
Define CUI, name who runs the CUI program, and identify which systems the 800-171 requirements reach.
Elena Ruiz, the contracts manager at Larkspur Precision Components, opens a new purchase order from a defense prime. It carries a page of contract clauses and a part drawing stamped as controlled.
She walks the drawing over to Dana Okafor, the ISSO. Dana asks three questions at once. Is this CUI? Who decides? And whose security rules do we follow for it?
Those questions have different owners. One organization runs the CUI program, another writes the security requirements, and a third puts them into your contract. This lesson sorts out which is which.
Under 32 CFR 2002, the federal CUI regulation, CUI is information the Government creates or possesses, or that an entity creates or possesses for or on behalf of the Government, that a law, regulation, or government-wide policy requires or permits an agency to handle using safeguarding or dissemination controls.
Two exclusions matter. Classified information is not CUI. And information a company keeps in its own systems that did not come from, and was not created for, the Government is not CUI either.
There are two flavors. CUI Basic is information where the underlying authority sets no specific handling rules, so the program's uniform controls apply. CUI Specified is information where the authority spells out its own handling controls. SP 800-171 defines the requirements for protecting CUI Basic on nonfederal systems, unless the underlying authority or an agreement says otherwise.
Executive Order 13556 created one government-wide CUI program. The National Archives and Records Administration (NARA) is its Executive Agent, and NARA has delegated that authority to the Director of the Information Security Oversight Office (ISOO).
The program's regulation, 32 CFR 2002, applies directly to executive branch agencies. It reaches non-executive-branch recipients, such as contractors, indirectly, through agreements like contracts.
NIST writes the security requirements in SP 800-171. NIST says they are intended for federal agencies to use in contracts and other agreements. NIST does not enforce them.
The agency decides what binds you, through contract terms and its own regulations. For defense work that is the Department of War (DoW), which the regulations still call DoD.
One exception: if you operate a system on behalf of an agency, SP 800-171 does not apply to that system. FISMA does.
Marcus Hill, the System Owner, asks the practical question: do we protect the whole shop network, or just the part that touches the drawings?
SP 800-171 answers it directly. The requirements apply only to components of nonfederal systems that process, store, or transmit CUI, or that provide protection for such components. Components include workstations, servers, network devices, virtual machines, databases, and applications.
NIST also says an organization that designates components for CUI may limit the scope by isolating them in a separate security domain, for example subnetworks behind firewalls or other boundary protection, with controls on information flow. The isolation can be physical, logical, or both.
The decision is Marcus's, and it has to be written down. Everything inside the line carries the requirements. Everything outside it should not touch CUI.
Lesson 2 — Where the Requirements Come From (~4 min)
The requirements are not invented. They are SP 800-53 Moderate, trimmed for confidentiality.
Explain how SP 800-171 was derived from the SP 800-53 Moderate baseline and read the structure of one requirement.
Dana Okafor has spent years on federal systems and knows the SP 800-53 Moderate baseline well. She opens SP 800-171 Rev 3 and counts families. Contingency planning is missing. So is program management. So is PII processing.
Her first thought is that the standard is incomplete. Her second thought is better: someone decided these did not belong, and wrote down why.
NIST did, and the reasons are in the publication. Reading them tells you what the standard is for.
NIST started with the controls in the SP 800-53B Moderate baseline. It then removed controls, or parts of controls, that were:
Primarily the responsibility of the Federal Government
Not directly related to protecting the confidentiality of CUI
Adequately addressed by other related controls
Not applicable
The result is a subset of controls needed to protect CUI. It rests on stated assumptions, including that CUI has the same value in federal and nonfederal systems and that its confidentiality impact is no less than moderate.
That last assumption comes from the CUI regulation, which categorizes CUI at no less than the FIPS 199 moderate confidentiality impact level.
SP 800-171 Rev 3 has 17 families. Rev 2 had 14. Rev 3 adds Planning, System and Services Acquisition, and Supply Chain Risk Management as families. Rev 2 had folded a few of those topics into other families by exception, for example the system security plan.
Three SP 800-53 families are left out of Rev 3, each for a stated reason:
PII Processing and Transparency. Personally identifiable information is itself a category of CUI, so no extra confidentiality requirements are needed.
Program Management. It is not associated with any control baseline.
Contingency Planning. It addresses availability. Two backup controls, CP-9 and CP-9(8), are included by exception to protect the confidentiality of backup information.
The pattern is the lesson: every omission traces back to the four tailoring reasons.
Take requirement 03.13.11, Cryptographic Protection. Its text reads, in substance: implement the following types of cryptography when used to protect the confidentiality of CUI, followed by a bracketed blank for the organization-defined types of cryptography.
Below the requirement sit two more parts. The Discussion says cryptography follows applicable laws and standards and that FIPS-validated cryptography is recommended. The References name the source control, SC-13, and a supporting publication, FIPS 140-3.
NIST states that the Discussion is informative, not normative. It does not extend the scope of a requirement, and its examples are notional.
So when an engineer asks whether FIPS-validated cryptography is mandatory, the Discussion alone does not settle it. The requirement text, the value assigned to that blank, and your contract do.
Lesson 3 — Rev 3 Structure: Parameters and Withdrawn Requirements (~4 min)
Rev 3 is more specific than Rev 2, and it hands you blanks to fill.
Describe what changed in Rev 3 and decide who must set the value of an organization-defined parameter.
NIST's own change log lists what Rev 3 did differently. The changes you will feel most:
It eliminated the distinction between basic and derived requirements.
It made requirements more specific, to cut ambiguity and clarify the scope of assessments.
It introduced organization-defined parameters (ODPs) in selected requirements.
It grouped requirements where possible, removed outdated and redundant ones, and added new ones.
It gave every requirement a title.
Rev 3 numbers requirements in the form 03.01.01, where the pair after the 03 is the family. Rev 2 used numbers like 3.1.1.
By a count of the published text, Rev 3 has 130 numbered entries, 33 of them withdrawn, leaving 97 active requirements. Rev 2 had 110 requirements in 14 families. Because requirements were grouped, removed, and added, do not assume a one-for-one match between editions.
Rev 3 keeps the numbers of requirements it withdrew. A withdrawn entry says so and names where the content went.
The clearest example is 03.12.04. It reads simply Withdrawn, incorporated into 03.15.02. In Rev 2 the requirement to develop and update system security plans was 3.12.4, inside the security assessment family. In Rev 3 it lives in the Planning family as 03.15.02, System Security Plan.
So a withdrawal is a move, not a deletion. When you update an older security plan template, follow the pointer instead of striking the requirement.
Some Rev 3 requirements contain bracketed blanks such as [Assignment: organization-defined time period]. These are organization-defined parameters, either assignments (fill in a value) or selections (choose from a list).
Two rules from NIST matter in practice:
Once a value is specified, it becomes part of the requirement.
If a federal agency or a consortium of agencies does not specify a value, the nonfederal organization must assign it. NIST does not set ODP values.
By a count from Appendix D, 50 of the 97 active requirements include at least one parameter, so this comes up constantly. The assessment procedures treat it seriously too: for any requirement with an ODP, the first thing an assessor checks is that the value has been defined.
Module 2 — Assess and Document
- Explain how SP 800-171A turns each requirement into determinations, methods, and objects
- Write the system security plan and the plan of action and milestones for a nonfederal system
Lesson 4 — Assessing with SP 800-171A (~4 min)
Every requirement has a matching test plan, and it is flexible on purpose.
Use SP 800-171A to describe how a requirement is assessed with examine, interview, and test, and what a finding means.
Priya Raman arrives to assess Larkspur. Dana has printed every policy she can find and asks Priya for the list of documents she must hand over.
Priya's answer surprises her. SP 800-171A says the potential assessment methods and objects it lists do not necessarily reflect actual compliance or noncompliance, there is no expectation about the number needed, and the entire list of objects should not be viewed as required artifacts.
What Priya needs for each requirement is enough evidence to answer the determination. Lesson 4 shows what that question looks like.
An assessment procedure has two halves: an assessment objective and a set of potential methods and objects.
The objective is a list of determination statements that begin Determine if:. If the requirement has an ODP, the first determination is that the ODP value is defined. The statements are linked to the requirement text so results trace back to it.
The IDs decode neatly. In A.03.01.06.ODP[01], the A means assessment, 03.01.06 is the requirement, ODP marks a parameter, and the bracketed number is its sequence. Square brackets also split a requirement into finer statements, such as A.03.01.12.a[01].
The procedure is the same shape for every requirement, so one example teaches the whole publication. A procedure's scope is guided by the system security plan.
The three methods describe the assessor's actions:
Examine: reviewing, studying, inspecting, or analyzing assessment objects.
Interview: holding discussions with individuals or groups about those objects.
Test: exercising objects under specified conditions to compare actual with expected behavior.
The objects are what gets assessed: specifications (documents), mechanisms (hardware, software, firmware safeguards), activities (protection-related actions involving people), and individuals. Methods also carry depth and coverage attributes, which set rigor and scope.
Results come out as satisfied or other than satisfied. Other than satisfied can mean anomalies to fix. It can also mean the assessor could not get enough information to decide.
Requirement 03.01.06 restricts privileged accounts and asks that people with them use non-privileged accounts for non-security work.
Its procedure has three determinations:
A.03.01.06.ODP[01]: the personnel or roles privileged accounts are restricted to are defined.
A.03.01.06.a: privileged accounts are restricted to those personnel or roles.
A.03.01.06.b: users with privileged accounts use non-privileged accounts for non-security functions and information.
The potential methods suggest where evidence may come from. Examine includes a list of privileged accounts, a list of system administration personnel, and system configuration settings. Interview includes system administrators and personnel with security responsibilities. Test includes the mechanisms that implement least privilege.
Notice that a policy alone answers none of the three determinations. They ask what is actually true on the system.
Lesson 5 — The SSP and POA&M for a Nonfederal System (~3 min)
Two documents carry most of the weight: what you have, and what you still owe.
Write what belongs in the system security plan versus the plan of action and milestones, including for specialized systems.
Requirement 03.15.02, System Security Plan, asks you to develop a plan that:
defines the constituent system components
identifies the information types processed, stored, and transmitted
describes specific threats of concern to the organization
describes the operational environment and its connections to other systems
gives an overview of the security requirements
describes the safeguards in place or planned
identifies the individuals who fill system roles
includes other information needed to protect CUI.
You must also review and update it at a frequency you define (an ODP) and protect it from unauthorized disclosure. It may be a collection of documents, including ones you already have, as long as the plan points to them.
In Rev 2 this was requirement 3.12.4. In Rev 3 it moved to the Planning family.
Requirement 03.12.02, Plan of Action and Milestones, has two parts. You develop a POA&M that documents planned remediation of weaknesses found in assessments and reduces or eliminates known vulnerabilities. And you update it from the findings of security assessments, audits or reviews, and continuous monitoring.
NIST adds that organizations use POA&Ms to describe how unsatisfied requirements will be met. The plan and the POA&M can be separate or combined. Federal agencies may treat both as inputs to risk-based decisions about whether CUI can be processed on a system a nonfederal organization hosts.
A caution about who decides what a POA&M may hold. NIST says what a POA&M is. A regulation or contract decides what open items it will accept. For example, the DFARS CMMC clause ties a conditional status to closing out a valid POA&M.
Marcus tells Dana that one of Larkspur's computer numerical control (CNC) machines runs a controller that cannot support a requirement, and the vendor will never change that.
SP 800-171 anticipates this. Specialized systems, and NIST names industrial control systems, medical devices, and CNC machines, may have limits on applying certain requirements. NIST's rule is:
Enduring exceptions are described in the system security plan (requirement 03.15.02).
Individual, isolated, or temporary deficiencies are managed through the POA&M (requirement 03.12.02).
The CNC controller is an enduring limit, so it belongs in the plan, along with the compensating safeguards Larkspur uses around it. A patch scheduled for next month is a temporary deficiency, so it belongs in the POA&M with a milestone and a date.
Module 3 — Which Edition Binds You, and What Is Changing
- Determine, from the regulation or contract rather than NIST's website, which edition applies
- Separate the stable obligations from the changing CMMC schedule, and know where to confirm current status
Lesson 6 — Which Edition Binds You (~4 min)
NIST wrote it. The regulation decides which edition you are held to.
Determine from the regulation or contract, not from NIST's publication page, which edition of 800-171 and 171A applies.
Dana pulls up two things. On NIST's site, SP 800-171 Rev 2 is marked withdrawn, superseded by Rev 3 in May 2024. In the folder from Elena, a defense contract refers to NIST SP 800-171 and to a program built around it.
Marcus asks the question that decides the budget: so which one do we build the security plan against?
It sounds like a NIST question. It is not. NIST decides which of its publications is current. The regulation decides which edition binds you. The rest of this lesson shows how to read that answer for yourself.
The CMMC program regulation, 32 CFR 170.14, says the CMMC model incorporates security requirements from three places: 48 CFR 52.204-21, NIST SP 800-171 R2, and selected requirements from NIST SP 800-172 Feb2021. It states that the Level 2 requirements are identical to the requirements in NIST SP 800-171 R2, and it prescribes assessment by SP 800-171A Jun2018.
The rule's incorporation-by-reference section, 170.2, pins the exact editions: SP 800-171 Revision 2, February 2020, including updates as of January 28, 2021, and SP 800-171A June 2018.
NIST has since withdrawn all of them. SP 800-171 Rev 2 and 171A (June 2018) were withdrawn May 14, 2024, and SP 800-172 (February 2021) on May 13, 2026. NIST's status and the regulation's text are separate facts.
When we checked on November 16, 2026, the eCFR showed no amendment to part 170 since December 2024.
Three instruments, three ways of naming the standard.
32 CFR 170.14 (CMMC). Names SP 800-171 R2 and 171A Jun2018 outright.
DFARS 252.204-7012 (MAY 2024). Requires the security requirements of SP 800-171 in effect at the time the solicitation is issued, or as the contracting officer authorizes. The edition depends on the contract's timing and on the contracting officer.
32 CFR 2002 (the CUI program rule). Its incorporation-by-reference section names the June 2015 edition of SP 800-171, with updates as of January 14, 2016, an edition older than Rev 2 and Rev 3. The same section says that to enforce any other edition, NARA must publish a notice in the Federal Register. That is the text codified in the eCFR as of November 13, 2026.
The habit to build: never assume one edition applies everywhere. Find the instrument that applies to your contract and read the edition it names. If you are unsure, your contracting officer or prime is the right person to ask.
Dana writes the method on the whiteboard.
1. Find the instrument. Read the clauses in the contract and note the clause date. Ask which regulations they invoke.
2. Read the edition it names. Use the regulation text, not a summary, and note any contracting officer authorization.
3. Build to that edition. Write the system security plan and POA&M against what is named.
4. Track the newer edition. Rev 3 is the current NIST publication and shows where requirements are heading. Map it, but do not assume a one-for-one match, since Rev 3 grouped, removed, and added requirements.
5. Record and re-check. Put the edition assumption and its source in the plan, and re-check when a clause, regulation, or contract changes.
Step 4 is where teams go wrong in both directions. Ignoring Rev 3 leaves you behind. Treating Rev 3 as your checklist when the contract names Rev 2 means you may build to the wrong list.
Lesson 7 — Status Now: What Is Stable and What Is Changing (~3 min)
Learn the structure that survives rule changes, and check the live source for the rest.
Separate the stable obligations from the changing CMMC schedule, and name where to confirm current status.
DFARS 252.204-7012 is the clause that makes SP 800-171 a contract duty for covered defense information. Its current text is dated MAY 2024, and the eCFR shows no change to it since then.
Three duties matter here:
Adequate security. Covered contractor information systems that are not operated on behalf of the Government must meet the SP 800-171 requirements, as the previous lesson explained.
Rapid reporting. Rapidly report means within 72 hours of discovery of a cyber incident. Reports go to DoD through its DIBNet portal, and you need a DoD-approved medium assurance certificate.
Cloud providers. An external cloud service provider that stores, processes, or transmits covered defense information must meet security requirements equivalent to the FedRAMP Moderate baseline, and must comply with the clause's reporting and forensic duties.
None of these waits on a CMMC phase.
What the primary sources confirm:
A DFARS final rule, effective November 10, 2025, added clause 252.204-7021, which requires a contractor to hold a current CMMC status at the level its contract names and to affirm compliance each year.
The rule text in 32 CFR 170.3 describes four phases, each beginning one calendar year after the last.
On July 13, 2026 the Department of War announced it was suspending phase two requirements and starting a 60-day review of the program. It said companies would still need to continue to meet phase one requirements.
What we could not confirm: the review's outcome. On November 16, 2026 we found no new CMMC rule in the Federal Register, and the eCFR text of part 170 had not changed. The Department's own CMMC page says program details are subject to change during rulemaking.
This course deliberately does not list CMMC level-by-level requirements or scoring. The program is under review, so use the Department's current resources and your contract for those.
Four habits carry across editions and schedules.
1. Read the clause and its date in every contract. That is what binds you.
2. Keep the durable documents current. A system security plan and a POA&M exist in both Rev 2 and Rev 3, so the work carries over.
3. Track the newest NIST edition as direction, without confusing it for the binding one.
4. Check the primary source, and date what you checked.
Where to check each fact:
What your contract requires: the contract and its clauses.
What a regulation says: the eCFR, noting its up-to-date date, and the Federal Register for new rules.
Whether a NIST publication is current or withdrawn: its page at NIST's Computer Security Resource Center.
Where the CMMC program stands: the Department's CMMC page and the Federal Register, not a vendor summary.
RMF Coach is an educational simulation and training product — not an authorization, and not affiliated with or endorsed by NIST or FedRAMP.